Which department should I go to for a Pulmonary function test? Points to note on the PFT report?

2022-06-17 10:06:47 147

As far as modern people are concerned, there is a growing awareness of health protection and disease prevention, and as a result, more and more of them are able to develop the habit and awareness of regular medical check-ups. Now that we are in the epidemic prevention and control phase, when the lungs are most vulnerable to strain and damage, many people give priority to having their lungs checked for medical check-ups.

However, many people who are interested in having their lungs checked are in a quandary: by definition, the lungs are in the chest cavity, but by function, they are part of the respiratory function. Should I go to a respiratory unit or a thoracic unit to have my lungs examined?

Should I go to a respiratory or a thoracic surgery department for a pulmonary measurement?

 

Whether you go to a respiratory department or a thoracic surgery unit, you will be guided through the correct procedure to get the test data you want.

However, there is a slight difference between a respiratory examination of the lungs and a thoracic examination of the lungs.

The thoracic surgery is more of a way to help assess some of the possible lung indications and determine if the patient needs clinical surgery. In general, patients with more serious lung disease need to be seen in thoracic surgery as a priority.

Respiratory medicine, on the other hand, is more concerned with assessing your lungs for signs of disease such as pulmonary nodules, alveolitis and other conditions, helping to determine whether the condition is benign or malignant, and providing a plan for medication accordingly.

In simple terms, thoracic surgeons are more oriented towards the diagnosis of serious lung disease and the assessment of surgical conditions.

Respiratory physicians, on the other hand, are more interested in examining the lungs for disease and providing appropriate management and medication plans.

Therefore, from the point of view of the pulmonary check-up itself, it is of course more advisable to go to a respiratory unit, and if the results of the respiratory examination are not promising, the relevant medical examination process of thoracic surgery is required if necessary.

Incidentally, in the event that certain lung diseases are detected, such as nodules, it is also recommended that you go to an imaging department for a review, as this will allow you to better understand and determine the benignity or malignancy of the nodule symptoms, so that you can better plan your medication and treatment. It is important to be aware of this.

So, how can I tell if I have the disease? Generally speaking, the doctor will tell us the answer when we get the check-up sheet, but it is also very important for the patient to have some awareness of the lung indicators and to be able to judge their own symptoms to help standardise and adjust treatment in their lives.

 Ancool Technology Co.,Ltd,ultrasonic pulmonary function testing,lung,spirometer,breath


What should I pay attention to on the PFT report?


① Spirometry Measurement

Simply put, it's a combination of how much air your lungs inhale or exhale, and how fast you breathe.The most important one is FEV1/FVC

What is the FEV1 / FVC?This is the percentage of air exhaled in the first second when each person exhales forcefully.Normally, the amount of air expelled or inhaled in the first second of breath is the highest and is the best indicator of the health of the airways in a person's lungs.The airway in the lungs is also the most prone to blockage or disease, so attention should be paid to it.

In general, the standard value of FEV1/FVC is between 70% and 85%, and friends can check on their own.


② Pulmonary Diffusion funtion measurement  

Helps the examiner measure the level of oxygen entering the blood from the alveoli, as well as the exchange capacity of carbon dioxide.It is an important means to evaluate the diffusion capacity of lung.

If this item is not met, it indicates poor lung diffusion and may be the presence of lung tissue damage, pulmonary edema, or clinical manifestations of pulmonary fibrosis.According to the medical definition, the normal value of dispersion function index is 3.3 ~ 4.6 mL • Kpa-1 /s.


③ Bronchial dilation testing

Numerous bronchi in the lungs, such as bronchitis, acute bronchitis, are also very common lung diseases.So the corresponding bronchial health indicator is also one of the best things that we know.

During the test, the doctor usually inhales bronchodilators, and then determines the likelihood of bronchial blockage by measuring FEV1 before and after the test.If the level of FEV1 increases by about 12% after inhaling the bronchodilator, the bronchodilation test can be tentatively positive and symptoms of bronchoconstriction or blockage may exist, requiring further examination and treatment.

In addition, in the lung physical examination, in order to obtain the most accurate data mentioned above, the standardization of the physical examination process and the strict implementation of some steps are also one of the methods to help us get more accurate physical examination data.

Ancool Technology Co.,Ltd,ultrasonic pulmonary function testing,lung,spirometer,breath

Pulmoanry function testing, what needs to be standardized behavior and attention?

① Try to breathe through your mouth.If the nose breathing is hastily used in the process of blowing, the amount of gas exchanged at the mouth will be reduced and the physical examination data will be deviated.

② Asthma patients take medicine before examination.Part of the lung examination of patients, there may be asthma or breathing symptoms, before the examination, it is best to take antiasthmatic drugs, let breathing smooth and then test, in order to obtain the most accurate examination data.

③ Breathe in as much as you can. Inhalation is one of the most important aspects of lung examination, which can obtain a series of examination data including bronchi, alveoli, gas dispersion and so on.And the premise of these data standards, the examiner needs to use the most extreme state of inhalation, as far as possible, so that the data out of the test is the most accurate.For the sake of health, also please friends must not be perfunctory, so as not to delay their health.

To sum up, lung physical examination seems to be simple, but there are still many indicators we need to know and possible precautions in physical examination. I hope to provide reference and help to friends in need.Under normal circumstances, it is best to recommend everyone to do a physical examination every other year or so, so that their health can be monitored and guaranteed.


SpiroPower® Angel


Pediatric “specialist” 

- Accurately measuring the patient whose weight is above 2KG  High sensitivity & low resistance ultrasonic sensor 

- Extremely high sensitivity & low flow, free resistance, accurately measure the VT of 5ml/kg 


Modular design to achieve different PFT function 

- Full Spirometry (Slow VC, Flow-Volume Loop, Tidal FVL, MVV), Bronchial dilation test(BDT) 

- DLCO, IOS, Bronchial provocation test optional 


Multiple predicted values Latest predicted values for pediatric pulmonary function testing 

Free cross infection, efficiently testing 


SpiroPower Angel is suitable for the patients with Low VT, low VC, high respiratory rate and poor coordination without sedation, NO cross infection


SpiroPower® Air Pro


Super sensitivity & low resistance ultra flow sensor 

- Accurate & reliable, excellent curve repeatability 


Modular design to achieve different PFT function 

- Full Spirometry (Slow VC, Flow-Volume Loop, Tidal FVL, MVV), Bronchial dilation test(BDT) 

- DLCO,IOS Bronchial provocation test optional Available for Adult or Children 

- Adults, children above five years old available


SpiroPower® Q

Adults, children above five years old available 


 Portable diagnostic device, mainly used for basic screening 

Main components: ventilation module (including RECO sensor), data connection line, software module and accessories (mouthpieces), computer(optional) 

Functions: Slow VC, Flow-Volume Loop, Tidal FVL, MVV, Bronchial dilation test(BDT)


YOUR BREATH , WE CARE !

Ultrasonic SpiroPower® Pulmonary Function Testing

Free Service Call: 023 4162 2982

Working Time:Monday to Friday 9:00~17:30

Email:info@ancool.com.cn

Call
Email
Map
QQ